dc.contributor.authorElton D.N.en_US
dc.contributor.authorArunachala U.C.en_US
dc.contributor.authorVijayan P.K.en_US
dc.date.accessioned2023-11-30T08:35:34Z-
dc.date.available2023-11-30T08:35:34Z-
dc.date.issued2020-
dc.identifier.issn0017-9310-
dc.identifier.otherEID(2-s2.0-85088929503)-
dc.identifier.urihttps://dx.doi.org/10.1016/j.ijheatmasstransfer.2020.120264-
dc.identifier.urihttp://localhost:8080/xmlui/handle/123456789/474-
dc.description.abstractDuring the past years, several studies were focused on the instability of single-phase rectangular natural circulation systems. However, experimental identification of instability threshold and categorization of instability regimes is of prime interest in many industrial applications which have been addressed by very few researchers that too limited to lower diameter loops only. Hence, in the present study, a larger diameter rectangular loop with horizontal heater horizontal cooler (HHHC) configuration has been designed to generate single phase natural circulation data on the steady state and stability behavior. Effect of different operating procedures (i.e., start-up from rest, power raising from stable steady state, and power reduction from an unstable state) on stability behavior are studied. Most of the oscillatory regimes are identified and noticed that the operating procedure can influence the instability threshold. The instability threshold was found to increase with the lowering of the coolant temperature and increasing its flow rate. The operating procedures i.e., power raising from stable steady state and start-up from rest gave the maximum and minimum values of the stability threshold respectively. As opposed to this, the minimum instability threshold in smaller diameter loops was reported for the operating procedure with power reduction from an unstable state. The experimental results confirm the occurrence of the hysteresis phenomenon. Due to the larger diameter and lower Lt/D ratio of the loop, all the oscillatory behaviors were aperiodic in nature in contrast to the observations in smaller diameter loops. © 2020en_US
dc.language.isoenen_US
dc.publisherElsevier Ltden_US
dc.sourceInternational Journal of Heat and Mass Transferen_US
dc.subjectCharacteristics of unstable oscillationsen_US
dc.subjectHorizontal heater horizontal cooleren_US
dc.subjectHysteresis phenomenonen_US
dc.subjectInstability behavioren_US
dc.subjectOperating procedureen_US
dc.subjectSingle-phase natural circulationen_US
dc.titleInvestigations on the dependence of the stability threshold on different operating procedures in a single-phase rectangular natural circulation loopen_US